Fronius IG 2000 / 3000 / 2500LV
![]() |
Zoom
close

The flexible PV inverter line.
Compact inverters: The Fronius IG line is perfect for smaller applications, such as residential systems. The different inverter types can be combined as required. Time proven Fronius technology gets the most out of all module types.
Compact inverters: The Fronius IG line is perfect for smaller applications, such as residential systems. The different inverter types can be combined as required. Time proven Fronius technology gets the most out of all module types.
Technical Data
|
Fronius IG |
IG 2000 |
IG 3000 |
IG 2500-LV |
|
|---|---|---|---|---|
|
DC Input Data |
||||
| Recommend PV power | 1500 - 2500 Wp | 2500 - 3300 Wp | 1800 - 3000 Wp | |
| 500 V | 500 V | 500 V | ||
| Operating DC voltage range | 150 - 450 V | |||
| Max. usable DC input current | 13.6 A | 13.6 A | 13.6 A | |
|
AC Output Data |
||||
| Max. Output power @ 40°C | 2000 W | 2700 W | 2350 W | |
| Nominal AC output voltage | 240 V | 240 V | 208 V | |
| Utility AC voltage range | 212 - 264 V (240 V + 10% / -12%) | 183 - 227 V | ||
| Maximum AC current | 8.35 A | 11.25 A | 11.25 A | |
| Max. utility back feed current | 0.0 A | 0.0 A | 0.0 A | |
| Operating frequency range | 59.3 - 60.5 Hz (60 Hz nom) | |||
| Total Harmonic Distortion THD | <5% | |||
| Power Factor (cos phi) | 1 | |||
|
General Data |
||||
| Max. Efficiency | 95.2% | 95.2% | 94.4% | |
| Consumption in stand-by | < 0.15 W (night) | |||
| Consumption during operation | 7 W | |||
| Enclosure | NEMA 3R | |||
| Size (l x w x h) | 18.8 x 16.5 x 8.8 inches (470 x 418 x 223 mm) | |||
| Weight | 26 lbs (11.8 kg) | |||
| Ambient Temperature Range | -13 to 122 °F (-25 to +50 °C) | |||
| Cooling | controlled forced ventilation, variable speed fan | |||
| Integrated AC and DC disconnects | standard UL approved DC & AC disconnects | |||
|
Protections |
||||
| Ground fault protection | Internal GFDI, in accordance with UL 1741 | |||
| DC reverse polarity | Internal diode | |||
| Islanding protection | Internal, in accordance with UL 1741, IEEE 1547 | |||
| Over temperature | Output power derating | |||
| Surge protection | Internadl DC & AC protection to 6 kV | |||
| Compliance | ||||
| Safety | UL 1741 | |||
| EMI | FCC Part 15; Class A & B | |||
| Anti-islandinig protection | UL 1741, IEEE 1547 | |||
| Ground fault detector and interruptor | Compliant with NEC Art. 690 requirements, UL 1741 | |||
| Miscellaneous | ||||
| Max. AC over current protection | Two-pole, 15 / 20 A circuit breaker | |||
| AC wire sizing | No. 14 - 6 AWG | |||
| DC wire sizing | No. 14 - 6 AWG | |||
| AC disconnect | 16 A | |||
| DC disconnect | 25 A | |||
| Warranty | 10 year Premium Warranty is standard | |||
Equipment features
- Fronius LC-Display
- HF-Transformer
- Module-Manager