Fronius IG 40 / 60 HV
![]() |

Higher yield due to work-sharing is achieved by linking the two power circuits using the MIX™ concept, our optimised master-slave system. In the part-load range only one of the two power stage sets operates, while both work together at full-load. The advantages are a noticeable increase in yield with a simultaneous reduction in operating hours.
As the input voltage range of the Fronius IG 60 has been expanded from the former 500 V to 530 V, longer module strings can be connected. Due to this improvement, the product name changed from “Fronius IG 60” to “Fronius IG 60 HV”. “HV” stands for “High Voltage”.
Technical Data
|
Fronius IG |
40 |
60 HV |
|---|---|---|
|
Input Data |
||
| MPP voltage range | 150 - 400 V | 150 - 400 V |
| Max. input voltage |
500 V | 530 V |
| PV system output | 3,500 - 5,500 Wp | |
| Max. input current | 29,4 A | 35,8 A |
|
Output Data |
||
| Nominal output | 3,500 W | 4,600 W *) |
| Max. power output | 4,100 W | 5,000 W |
| Max. efficiency | 94,3 % | 94,3 % |
| Euro efficiency | 93,5 % | 93,5 % |
| Mains voltage /frequemcy | ||
| Distortion factor | < 3,5 % | |
| Power factor | 1 | |
| Power consumption at night | 0 W | |
|
General Data |
||
| Size l x w x h | 610 x 344 x 220 mm | |
| Weight | 16 kg (20 kg) | |
| Cooling | controlled forced-air cooling | |
| Protection class (housing) | IP 21 (IP 45) | |
| Ambient temperature range | - 20 ... 50° C | |
| Permissible humidity | 0 ... 95 % | |
|
Protective Devices |
||
| DC insultion measurement | warning when Riso < 500 k Ohm | |
| Polarity reversal protection | built-in | |
| Behaviour on DC overload | displacement of operating point | |
*) Important note:
Fronius IG 60 HV with Setup ES and Setup IT are supplied with a nominal output of 5.000 W!
The right to make technical modifications is reserved.
Equipment features
- Fronius LC-Display
- HF-Transformer
- Module-Manager
- MIX-Concept
Documents and downloads
Technology
Fronius MIX™ technology The cleverly-devised combination of several power modules means Fronius inverters always achieve maximum yield, even when in the partial-load range. This is all down to the unique Fronius Master Inverter X-Change system (MIX™), a development of the classic master/slave principle. How it works: all power modules are equal. The „master“ is allocated alternately, taking into account the operating hours worked. The result is that loads are applied evenly to individual power modules and the operating time decreases.
HF transformer switchover Fronius transformer inverters use a high-frequency (HF) transformer. The automatic transformer switchover facility produces three efficiency peaks. The result: a constant level of efficiency across the entire input voltage range, resulting in higher yields. Other advantages of HF transformer technology are the compact, lightweight design, a high level of efficiency and safety as a result of the electrical isolation.
Fronius Module Manager The Fronius Module Manager always locates the maximum power point (MPP), even in the case of the more demanding thin-layer modules. The Fronius Module Manager achieves an outstanding MPP adaptation efficiency of >99.9 % in total.
PC board replacement The foundation of the unique PC board replacement is laid as we develop our inverters, as PC boards can only be replaced if the device has been designed accordingly. This enables our Fronius Service Partners to provide the fastest inverter servicing on the market.