2-phase inverter with 8 kW max. output, best suited for large pv systems. Also available in a one phase version.
 

Technical Data


Fronius IG Plus
35 
50
70 
100
 120
150
Input data
           
DC normal capacity  3700 W  4200 W  6800 W  8400 W  10500 W  12600 W
MPP voltage range  230 - 500 V  230 - 500 V  230 - 500 V  230 - 500 V  230 - 500 V  230 - 500 V
Max. input voltage range
(for 1000 W/m², -10°C)
 600 V  600 V  600 V  600 V  600 V  600 V
Max. input  16.0 A  18.3 A  29.7 A  36.6 A  45.8 A  54.9 A
 
Output data
           
AC nominal capacity  3500 W  4000 W  6500 W  8000 W  10000 W  12000 W
Max. output  3500 W  4000 W  6500 W  8000 W  10000 W  12000 W
Max. efficiency  96.0 %  96.0 %  96.0 %  96.0 %  96.0 %  96.0 %
Euro efficiency  95.0 %  95.1 %  95.4 %  95.5 %  95.5 %  95.5 %
MPP adaption efficiency  99.9 %  99.9 %  99.9 %  99.9 %  99.9 %  99.9 %
Main voltage / Frequency  230 V 50 Hz (60 Hz)
Power connection  1-phase  2-phase 
 (optional 1-phase)
 3-phase
Harmonic distortion  < 3.5 %
Power factor  1
Power consumption at night  1 W
 
General data
           
Measurements
(h x w x d)
 631 x 434 x 244 mm  926 x 434 x 244 mm  1221 x 434 x 244 mm
Connection area weight  11 kg  11 kg  11 kg  11 kg  11 kg  11 kg
Power area weight  14 kg  14 kg  26 kg  26 kg  38 kg  38 kg
Protection class  IP 44  IP 44  IP 44  IP 44  IP 44  IP 44
Inverter concept  HF transformer
Cooling  regulated cooling
Housing  Metal housing for inside and outside installation
Ambient temperature range  from -20°C to + 50°C
Permitted humidity  0 % to 95 %
 
Safety equipment
           
DC isolation measurement  Warning at RISO<500k Ohm
Overload behavior  Operating point shift, power limiter
DC circuit breaker  integrated
 
The right to make technical modifications is reserved.

Equipment features


Grounding on site.

You decide on site, whether or not you want or need to ground the modules. Insert fuse, activate the software - grounding is complete.

 

For inside and out.

All Fronius IG Plus devices have a robust, well-designed metal housing. UV-resistance and corrosion-protection enable them to be used both inside and out. 

 

Integrated DC disconnect.

No additional installation or cabling is necessary. The highest comfort and safety as per DIN-VDE 0100-712.

 

The new power plug system.

The connection area and power modules are installed seperately from each other. Very easy, very safe: The connection area is attached to the wall as normal. Then the power module is simply plugged in. The power plug connects both parts into one secure unit. When service is required, the connector remains on the wall - all settings and configurations remain untouched.

 

Technology


3 efficiency peaks.

More earnings for every system size: The automatic transformer switching function of the Fronius IG Plus makes sure of this. This enables not one, but three equal efficiency peaks. The result: Constant efficiency over a wide input voltage range.

In comparison: The efficiency of inverters without transformer switching declines steadily with an increasing input voltage. Devices without a transformer only have one efficiency peak. 

With a 96.0 % maximum efficiency, the Fronius IG Plus series scores the highest grade among HF devices.

 

MIX-Concept.

You get the maximum out of partial load ranges, e.g. on cloudy days, through a clever combination of several power modules. The power modules in Fronius devices divide up the work depending on the operating hours. 

 

Module Manager.

Whoever can always remain at the maximum power point (MPP), can get the most out of each ray of light. This is the job of the Module Manager: For fast, exact MPP tracking. This is especially important for thin-layer modules whose efficiency characteristics are more even. 

 

Well thought out ventilation concept.

Disruptive ambient factors such as dust or moisture remain on the outside: The reason: Cooling air is drawn in on the wall side and routed through a closed channel over the heat sink. This prevents contact with the circuit board. At the same time, the components are kept cool - the device operates with a stable consistency.


 

Glossary