Fronius IG TL 5.0

Zoom
Bild zurück
close
x
Get plugged into the future!

System monitoring with the Status Manager comes standard with the Fronius IG TL. This includes following features:
  • String malfunction detection
  • Detailed status codes
  • Direct signaling contact

The Status Manager immediately reports any problems throughout the entire system thus locking in system yields for the long-term.

It also has a unique feature in which a commercially-available USB stick can be used for easy system monitoring as well as simple inverter updating.

 

Technical Data


INPUT DATA Fronius IG TL 5.0
DC maximum power 5250 W
Max. input current 15.0 A
Max. input voltage 850 V
MPP voltage range 350 - 700 V
OUTPUT DATA
AC nominal output 4600 W* / 5000 W
Max. output power 5000 W
Max. output current 21.7 A
Max. efficiency 97.7 %
European efficiency 97.3 %
MPP adjustment efficiency 99.9 %
Mains connection 1~NPE 230 V
Frequency 50 Hz / 60 Hz
Distortion factor < 3 %
Power factor 1
Nighttime consumption < 1 W
GENERAL DATA
Dimensions (H x W x  D) 597 x 413 x 195 mm
Weight 19.1 kg
Degree of protection IP 55
Inverter Transformerless
Cooling Controlled air cooling
Installation Indoors and outdoors
Ambient temperatur range -20°C to +55°C
Permitted humidity 0 % to 95 %
PROTECTIVE EQUIPMENT
DC insulation measurement Universal-current-sensitive fault monitoring
Overload behaviour Operating point adjustment, power limitation
DC disconnector Integrated
INTERFACES
USB A socket For USB sticks** no bigger than
80 x 33 x 20 mm (L x W x H)
Signalling output (NO contact) 2-pin screw terminal, 12V max. 300 mA
2x RJ45 sockets (RS485) Solar Net interface, interface protocol

 
*   Fronius IG TL 5.0 devices for Germany, Austria, Belgium and Czech Republic have an AC nominal output of 4600 W.


* *Please refer to the information in the operating instructions regarding the use of USB sticks (temperature range).
 
The right to make technical modifications is reserved.

Equipment features


Direct signaling contact.
A warning signal (e.g. indicator light or buzzer) can be activated when there are status changes via the 12 V signal output integrated into the inverter. Malfunctions are reported immediately.


Night display.
System information 24/7. The matrix display shows the most important information regardless of whether or not the inverter is in operation. This is made
possible via the AC side power supply. For example, this enables you to access daily system data on the display even after sundown – including any status messages.


Integrated Solar Net interface.
Other components for system monitoring (e.g. Fronius Datalogger) can be connected directly to the inverter through the standard Solar Net interface. This enables you to easily integrate high-end system monitoring that is 100% compatible with all other Fronius IG inverters as well as the comprehensive Fronius DATCOM world.


DATCOM-Slot.
The DATCOM slot can be used for connecting the USB stick, optional DATCOM components as well as the direct signaling contact. It opens like a drawer providing easy access. Additional components can be connected later on as required.


Service-friendly installation system.
The connection area and power module are installed separately from each other. Time-consuming cabling is no longer required. When service is needed, the connector remains on the wall and the DATCOM slot remains onsite – all settings and configurations remain untouched. The standard string monitoring system checks the current of up to 6 strings.

Technology


String malfunction detection.
The inverter continually compares the string currents of connected strings with each other. This enables the early detection of problems in the entire system (e.g. gnawing damage to cables from small animals, module failure, etc.). This can help to prevent an incremental loss of earnings.


Detailed status codes.
Should any problems occur in the system, comprehensive and precise service codes are displayed. This makes it easier to isolate the exact source of the error and saves valuable time for fault diagnostics and correction.


The highest efficiency via the Module Manager.
Whoever can always remain at the maximum power point (MPP), can get the most out of each ray of light. This is the job of the Fronius Module Manager with its accurate MPP tracking.


Easy data exchange via USB.
Ein handelsüblicherUSB-Stick, der am Wechselrichter angestecktwerden kann, sammelt die Daten während der Betriebszeiten.Die Anlageninformationen können somit jederzeit in den PC eingespeist und mit der Software Fronius Solar.access ausgewertet und archiviert werden. Aufwändige Verkabelungsarbeiten sind also nicht mehr
nötig. Einfach DATCOM-Slot herausziehen, USB-Stick entnehmen und die Daten auf den PC laden.


Update via USB.
A commercially-available USB stick that can be inserted into the inverter collects data during operation. System information can then be moved to a PC at any time and then analyzed and archived using Fronius Solar.access software. Timeconsuming cabling is no longer required. Simply pull out the DATCOM slot, remove the USB stick and load the data to your PC.


Completely heat and dust-free ventilation concept.
The well-thought-out ventilation concept precludes overheating or contamination. The device body is hermetically sealed. Only the cooling fins for the electronics remain on the outside. The electronicsare air-cooled. The temperature-controlled fan circulates outside air through the cooling fins as required. This ensures that the inside of the device remains significantly cooler and that there is absolutely no exchange between inside and outside air.