The Powerhouse

Higher yield due to work-sharing is achieved by linking the two power circuits using the MIX™ concept, our optimised master-slave system. In the part-load range only one of the two power stage sets operates, while both work together at full-load. The advantages are a noticeable increase in yield with a simultaneous reduction in operating hours.

As the input voltage range of the Fronius IG 60 has been expanded from the former 500 V to 530 V, longer module strings can be connected. Due to this improvement, the product name changed from “Fronius IG 60” to “Fronius IG 60 HV”. “HV” stands for “High Voltage”.

 

Technical Data


Fronius IG 
40 
60 HV 
Input Data 
MPP voltage range  150 - 400 V  150 - 400 V 
Max. input voltage (at 1000 W/m²; - 10° C)  500 V  530 V 
PV system output  3500 - 5500 Wp  4600 - 6700 Wp  
Max. input current  29,4 A  35,8 A
Output Data 
Nominal output  3500 W  4600 W *)
Max. power output  4100 W   5000 W 
Max. efficiency  94,3 %   94,3 %  
Euro efficiency  93,5 % 93,5 %  
Mains voltage /frequemcy  230 V / 50 Hz (60 Hz)
Distortion factor  < 3,5 %  
Power factor  1  
Power consumption at night  0 W 
General Data 
   
Size l x w x h   610 x 344 x 220 mm (733 x 435 x 225 mm) 
Weight  16 kg (20 kg) 
Cooling  controlled forced-air cooling 
Protection class (housing) IP 21 (IP 45)
Ambient temperature range  - 20 ... 50° C 
Permissible humidity  0 ... 95 % 
Protective Devices 
   
DC insultion measurement  warning when Riso < 500 k Ohm 
Polarity reversal protection  built-in 
Behaviour on DC overload  displacement of operating point 
     

*) Important note:
    Fronius IG 60 HV with Setup ES and Setup IT are supplied with a nominal output of 5.000 W!