Fronius IG 2000 / 3000 / 2500LV
![]() |
Zoom
close

The reliable PV inverter series.
The Fronius IG series has proven itself to be powerful, user-friendly and highly reliable. Equipped for every size of PV system, especially for smaller systems (e.g. on the roof of a one-family home). The combination of different types available for selection is limitless. The ingenious processor control combined with the powerful HF transformer extracts the maximum energy yield from all types of modules.
Operating Manual
The Fronius IG series has proven itself to be powerful, user-friendly and highly reliable. Equipped for every size of PV system, especially for smaller systems (e.g. on the roof of a one-family home). The combination of different types available for selection is limitless. The ingenious processor control combined with the powerful HF transformer extracts the maximum energy yield from all types of modules.
Operating Manual
Technical Data
|
Fronius IG |
IG 2000 |
IG 3000 |
IG 2500-LV |
|
|---|---|---|---|---|
|
DC Input Data |
||||
| Recommend PV power | 1500 - 2500 Wp | 2500 - 3300 Wp | 1800 - 3000 Wp | |
| 500 V | 500 V | 500 V | ||
| Operating DC voltage range | 150 - 450 V | |||
| Max. usable DC input current | 13.6 A | 13.6 A | 13.6 A | |
|
AC Output Data |
||||
| Max. Output power @ 40°C | 2000 W | 2700 W | 2350 W | |
| Nominal AC output voltage | 240 V | 240 V | 208 V | |
| Utility AC voltage range | 212 - 264 V (240 V + 10% / -12%) | 183 - 227 V | ||
| Maximum AC current | 8.35 A | 11.25 A | 11.25 A | |
| Max. utility back feed current | 0.0 A | 0.0 A | 0.0 A | |
| Operating frequency range | 59.3 - 60.5 Hz (60 Hz nom) | |||
| Total Harmonic Distortion THD | <5% | |||
| Power Factor (cos phi) | 1 | |||
|
General Data |
||||
| Max. Efficiency | 95.2% | 95.2% | 94.4% | |
| Consumption in stand-by | < 0.15 W (night) | |||
| Consumption during operation | 7 W | |||
| Enclosure | NEMA 3R | |||
| Size (l x w x h) | 18.8 x 16.5 x 8.8 inches (470 x 418 x 223 mm) | |||
| Weight | 26 lbs (11.8 kg) | |||
| Ambient Temperature Range | -5 to 122 °F (-20 to +50 °C) | |||
| Cooling | controlled forced ventilation | |||
| Integrated AC and DC disconnects | standard UL approved DC & AC disconnects | |||
|
Protections |
||||
| Ground fault protection | Internal GFDI, in accordance with UL 1741 | |||
| DC reverse polarity | Internal diode | |||
| Islanding protection | Internal, in accordance with UL 1741, IEEE 1547 | |||
| Over temperature | Output power derating | |||
| Surge protection | Internadl DC & AC protection to 6 kV | |||
| Compliance | ||||
| Safety | UL 1741 | |||
| EMI | FCC Part 15; Class A & B | |||
| Anti-islandinig protection | UL 1741, IEEE 1547 | |||
| Ground fault detector and interruptor | Compliant with NEC Art. 690 requirements, UL 1741 | |||
| Miscellaneous | ||||
| Max. AC over current protection | Two-pole, 15 / 20 A circuit breaker | |||
| AC wire sizing | Use maximum AWG 6 194 °F (90 °C) copper wire | |||
| DC wire sizing | Use maximum AWG 8 194 °F (90 °C) copper wire | |||
| AC disconnect | 16 A | |||
| DC disconnect | 25 A | |||
| Warranty | 10 year Premium Warranty is standard | |||
Equipment features