Fronius Technical Bulletin: State Code 530
04/07/2009
Explanation and Resolution
Explanation
State code 530 is an information display of an automated process and not an indication of a failure, safety risk or any interruption in power production within the IG Series inverters (the IG Plus series of inverters are not affected by State Code 530). The GFDI-2 card contains two sets of software, one which operates within the processor and a back up or archived set of software permanently stored on memory within the GFDI-2 card. During the start-up sequence, or low power from the Solar Array certain circumstances can cause a momentary disruption of communication between the GFDI-2 card and the inverter processor. This can result in a slight change in the software operating within the GFDI-2 card which is automatically detected and restored to the factory default setting from the archived memory and the message State Code 530 is displayed. This activity is done seamlessly and without any interruption whatsoever in power
production.
Resolution
Affected Inverters
Installers can upgrade any affected inverter by replacing the GFDI-2 card in the Plug-n-Play section of the inverter. It is estimated that this process will take between 15 to 30 minutes. Fronius will pay for shipping the replacement card and return of the old card as well as provide service reimbursement of $175.00 per qualifying GFDI-2 card replacement (once the old card is returned). The reimbursement will be in the form of a credit to your distributor or check to the company doing the replacement of the GFDI-2 card.
Please contact our technical support at (810) 220-4414 with serial number of the affected inverter to proceed.
It is our goal to resolve this quickly and with minimum inconvenience. Fronius appreciates your business and continued support.
Best Regards,
Gord Petroski
Director Fronius USA
Solar Electronics Division
en