Digital Operating Instruction
Clear HTML version of the operating instructions. Mobile and optimised for every device.
Number of MPP trackers | 1 |
---|---|
Max. PV input power | 8000 W |
Max. input current (Idc max) | 1 x 16 A |
Max. short circuit current, module array | 24 A |
DC input voltage range (Udc min - Udc max) | 150 - 1000 V |
Feed-in start voltage (Udc start) | 200 V |
Nominal input voltage (Udc,r) | 595 V |
MPP voltage range (Umpp min - Umpp max) | 320 - 800 V |
Usable MPP voltage range | 150 - 800 V |
Number of DC connections | 2 |
Maximum output power to battery | Dependent on connected Battery |
---|---|
Maximum input power from battery | Dependent on connected Battery |
AC nominal output (Pac,r) | 5000 W |
---|---|
Max. output power (Pac max) | 5000 VA |
Max. grid power demand | 5000 VA |
Max. AC output current | 8,3 A |
Grid connection (Uac,r) | 3~ NPE 400/230, 3~ NPE 380/220 V |
AC voltage range (Umin - Umax) | 150 - 280 V |
Frequency (fr) | 50 / 60 Hz |
Frequency range (fmin - fmax) | 45 - 65 Hz |
Total harmonic distortion | < 3 % |
Power factor (cos φac,r) | 0,85 - 1 ind,/cap, |
Width | 431 mm |
---|---|
Height | 645 mm |
Depth | 204 mm |
Weight | 19,9 kg |
Degree of protection | IP 65 |
Protection class | 1 |
Overvoltage category (DC / AC) 1) | 2 / 3 |
Night-time consumption | < 1 W |
Inverter design | Transformerless |
Cooling | Regulated air cooling |
Installation | Indoors and outdoors |
Ambient temperature range | -25°C - +60°C |
Permitted humidity | 0 - 100 % |
Max. altitude 2) | 2,000 m |
DC PV connection technology | 2x DC+ and 2x DC- screw terminals 2.5 - 16 mm² |
DC battery connection technology | 1x DC+ and 1x DC- screw terminals 2.5 - 16 mm² |
AC connection technology | 5-pin AC screw terminals 2.5 - 16 mm² |
Emergency power compatible | Yes |
Certificates and compliance with standards | VDE AR N 4105, ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1 |
Compatible batteries | Battery-Box H 6.4, 7.7, 9.0, 10.2, 11.5 Battery-Box Premium HVM 8.3, 11.0, 13.8, 16.6, 19.3, 22.1* |
Interference emission class | B |
Max. efficiency (PV - grid) | 97,9 % |
---|---|
Max. efficiency (PV - battery - grid) | > 90,0 % |
European efficiency (ηEU) | 96,0 % |
η at 5% Pac,r 3) | 81,6 / 81,6 / 73,4 % |
η at 10% Pac,r 3) | 89,2 / 92,5 / 89,7 % |
η at 20% Pac,r 3) | 93,2 / 95,3 / 94,2 % |
η at 25% Pac,r 3) | 94,0 / 96,5 / 95,3 % |
η at 30% Pac,r 3) | 94,5 / 96,7 / 96,0 % |
η at 50% Pac,r 3) | 95,3 / 97,5 / 96,8 % |
η at 75% Pac,r 3) | 95,6 / 97,9 / 97,3 % |
η at 100% Pac,r 3) | 95,8 / 97,9 / 97,5 % |
MPP adaptation efficiency | > 99,9 % |
DC insulation measurement | Integrated |
---|---|
Overload behaviour | Operating point shift, power limitation |
DC disconnector | Integrated |
DC Reverse polarity protection | Yes |
Integral RCMU | Yes |
WLAN / Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
---|---|
Datalogger and web server | Integrated |
Interface to battery and meter | Modbus RTU (RS485) |
Clear HTML version of the operating instructions. Mobile and optimised for every device.
The deliberate design of the Fronius SnapINverter meets great enthusiasm of our installers and customers.
1) According to IEC 62109-1.
2) Unrestricted voltage range.
3) And at Umpp min / Udc,r / Umpp max.