The current page does not exist in the target language.

Do you want to change the language and go to the home page or do you want to stay on the current page?

Change Language
SOLAR ENERGY
INSTALLERS & PARTNERS

$name

Please choose your desired product.

Product details

INPUT DATA

Number of MPP trackers1
Max. input current (Idc max)
47,7 A
Max. short circuit current, module array*
98 A
DC input voltage range (Udc min - Udc max)
580 - 1000 V
Feed-in start voltage (Udc start)
650 V
Nominal input voltage (Udc,r)
580 V
MPP voltage range (Umpp min - Umpp max)
580 - 850 V
Usable MPP voltage range580 - 850 V
Number of DC connections6
Max. PV generator power (Pdc max
37,8 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)
27 kW
Max. output power (Pac max)
27 kVA
AC output current (Iac nom)
40,9 / 39,1 A
Grid connection (Uac,r)
3~ NPE 400/230, 3~ NPE 380/220 V
AC voltage range (Umin - Umax)
150 - 275 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45 - 65 Hz
Total harmonic distortion<3% @Pnom (230/400VAC 50Hz)
Power factor (cos φac,r)
0 - 1 ind,/cap,

GENERAL DATA

Width
512 mm
Height
751 mm
Depth
227,5 mm
Weight35,5 kg
Weight incl. packaging39,5 kg
Degree of protectionIP 66
Protection class1
Overvoltage category (DC / AC) 1)
2 / 3
Night-time consumption< 1 W
Inverter designTransformerless
CoolingRegulated air cooling
InstallationIndoors and outdoors
Ambient temperature range-25°C - +60°C
Permitted humidity0 - 100 %
Max. altitude 2)
2,000 m / 2500 m
DC connection technology6x DC+ and 6x DC- screw terminals 2.5 - 16 mm²
AC connection technology5-pin AC screw terminals 2.5 - 16 mm²
Certificates and compliance with standardsÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727,
AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G99, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21
Noise emission60,3 dB(A)
Interference emission classB

EFFICIENCY

Max. efficiency (PV - grid)98,3 %
European efficiency (ηEU)98,0 %
η at 5% Pac,r 3)
95,9 / 93,1 %
η at 10% Pac,r 3)
96,8 / 95,7 %
η at 20% Pac,r 3)
97,7 / 97,1 %
η at 25% Pac,r 3)
98,1 / 97,3 %
η at 30% Pac,r 3)
98,1 / 97,4 %
η at 50% Pac,r 3)
98,3 / 97,5 %
η at 75% Pac,r 3)
98,2 / 97,6 %
η at 100% Pac,r 3)
98,1 / 97,5 %
MPP adaptation efficiency> 99,9 %

PROTECTION DEVICES

DC insulation measurementYes
Overload behaviourOperating point shift, power limitation
DC disconnectorYes
Integrated string fuse holderYes
DC Reverse polarity protectionYes

INTERFACES

WLAN / Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputsInterface to ripple control receiver
USB (type A socket) 4)
Data logging, inverter update via USB flash drive
2x RS422 (RJ45 socket) 4)
Fronius Solar Net
Signalling output 4)
Energy management (floating relay output)
Datalogger and web serverIntegrated
External input 4)
S0 meter connection / Evaluation of overvoltage protection
RS485Modbus RTU SunSpec or meter connection

Fodnoter til de tekniske data

1) Ifølge IEC 62109-1. Skinne til ekstra overspændingsbeskyttelse type 1 + 2 eller type 2 forefindes. 

2) Ubegrænset spændingsområde. 

3) Og ved Umpp min / Udc,r / Umpp maks.

4) Leveres også i light-versionen. 

 

* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g.: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.



We think you are located in a different country

The country currently selected is Denmark. Would you like to stay on this page or do you want to switch to the local website?