The current page does not exist in the target language.

Do you want to change the language and go to the home page or do you want to stay on the current page?

Change Language
SOLAR ENERGY
INSTALLERS & PARTNERS

Fronius Symo GEN24 Plus

Inverter for private PV systems with PV Point or Full Backup

Our three-phase Fronius GEN24 Plus hybrid inverter is the ideal core for private PV systems. The Fronius GEN24 Plus offers an integrated basic backup power supply with PV Point and even a full backup power solution through the option of connecting a battery storage system.
 
The Fronius GEN24 Plus hybrid inverter uses a battery storage system to enable self-sufficient energy production for electricity, heating, cooling and e-mobility. Fronius GEN24 Plus with Full Backup* also has a backup power solution that can supply even three-phase consumers – such as heat pumps. Thanks to Multi Flow Technology, the hybrid inverter can even handle parallel energy flows in the system in backup power mode.
 
* Available on the Fronius Primo GEN24 Plus 3-6 kW as well as the Fronius Symo GEN24 Plus 6-10 kW. 
Please choose your desired product.

Product details

INPUT DATA

Number of MPP trackers2
Max. PV input power
3150 W
Max. input current (Idc max)
12,5 A / 12,5 A
Max. short circuit current, module array*
20,0 A / 20,0 A
DC input voltage range (Udc min - Udc max)
80-1000 V
Feed-in start voltage (Udc start)
80 V
Nominal input voltage (Udc,r)
610 V
MPP voltage range (Umpp min - Umpp max)
125-800 V
Usable MPP voltage range80-800 V
Number of DC connections2+1
Max. PV generator power (Pdc max
4,5 kWpeak

OUTPUT DATA

AC nominal output (Pac,r)
3000 W
Max. output power (Pac max)
3000 VA
Max. grid power demand10 VA
Max. AC output current8 A
Grid connection (Uac,r)
3~NPE 230V / 400V, 3~NPE 220V / 380V
AC voltage range (Umin - Umax)
154-280 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45-66 Hz
Total harmonic distortion<3,5%
Power factor (cos φac,r)
0,7-1 ind,/cap,
Back-up power1 ~ NPE 220 V / 230 V
Nom. AC-Ausgangsstrom (380VAC)
4,5 A
Nom. AC-Ausgangsstrom (400VAC)
4,3 A

GENERAL DATA

Length
530 mm
Width
474 mm
Height
165 mm
Weight15,61 kg
Weight incl. packaging19,35 kg
Degree of protectionIP66
Protection class1
Overvoltage category (DC / AC) 1)
2/3
Night-time consumption<10 W
Inverter designTransformerless
CoolingRegulated air cooling
InstallationIndoor and outdoor installation
Ambient temperature range-25 - +60°C
Permitted humidity0 - 100%
Max. altitude 2)
3000m / 4000m
DC PV connection technology3x DC+ and 3x DC- push-in spring terminals 2.5 - 10 mm²
DC battery connection technology1x BATT+ and 1x BATT- push-in spring terminals 2.5 - 10 mm²
AC connection technology5 pole AC push-in spring terminals 1.5 - 10 mm²
3 pole backup power push-in spring terminals 1.5mm² - 10mm²
5x PE-screw terminals 2.5 - 16 mm²
Certificates and compliance with standardsIEC 62109, IEC 62116, IEC 61727, IEC 62909, VDE 0126, VDE AR-N4105, AS/NZS 4777.2, EN 50549, CEI 0-21, G 98, R25 6)
Back-up power functionsPV Point
Compatible batteries 5)
BYD Battery-Box Premium HVS/HVM 4) & LG RESU FLEX
Interference emission classB

EFFICIENCY

Max. efficiency (PV - grid)98,1 %
European efficiency (ηEU)96,7%
η at 5% Pac,r 3)
86,8%
η at 10% Pac,r 3)
92,4%
η at 20% Pac,r 3)
95,7%
η at 25% Pac,r 3)
96,3%
η at 30% Pac,r 3)
97,0%
η at 50% Pac,r 3)
97,6%
η at 75% Pac,r 3)
97,9%
η at 100% Pac,r 3)
98,1%
MPP adaptation efficiency99,9%

PROTECTION DEVICES

DC insulation measurementYes
Overload behaviourInterface to ripple control receiver, energy management
DC disconnectorYes
DC Reverse polarity protectionYes

INTERFACES

WLAN / 2x Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6x digital in/out + 6x digital inInterface to ripple control receiver, energy management
Emergency stop (WSD)Yes
Datalogger and web serverIncluded
2x RS485Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot

OUTPUT DATA PV POINT

Max continuous output power3000 VA
Nom. output current (Iac max)
13 A
Grid connection1 ~ NPE 220 V / 230 V
Frequency50 Hz / 60 Hz
Switchover time90 s

BATTERY CONNECTION

Number of DC connections1
Max. input current (Idc max.)
12,5 A
Max. input / output power (Depending on the connected battery)3150 W
Min. DC input voltage160 V
Max. DC input voltage531 V
More information about the features of this product
Clear HTML version of the operating instructions. Mobile and optimised  for every device.
Information for installation and commissioning

Downloads

Show all downloads for product

FOOTNOTES FOR TECHNICAL DATA 

1) According to IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK 

2) Unrestricted / restricted voltage range.

3) At Udc,r

4) This does not apply to the BYD Battery-Box Premium HVS 12.8 & HVM 8.3

5) Depending on the country-specific certification and availability

6) You can find the current certificates under www.fronius.com/symo-gen24-plus-cert 

 

* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g..: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.


We think you are located in a different country

The country currently selected is South Africa. Would you like to stay on this page or do you want to switch to the local website?