Cybersecurity Recommendations for Fronius Inverter Installations
Modern Fronius inverter platforms provide extensive network connectivity for monitoring, configuration, update, and integration with energy management systems and smart tariff solutions. These capabilities are secured by design through the use of industry-standard cryptographic mechanisms and secure default configurations that help minimize the potential attack surface.
However, cybersecurity is not solely determined by the inverter itself. When deployed within residential, commercial, or industrial networks, the overall security posture also depends on the surrounding network infrastructure and configuration. Unsecured networks, outdated devices, or weak access controls can increase the risk of unauthorized access, data loss, or disruption of system operation.
To enhance the security of installed systems, Fronius recommends implementing the following best practices.
1. Use a Private and Secure Network
Inverters and connected system components should only be operated within a trusted, private network environment. For wireless installations, WiFi networks should be protected with WPA2-PSK at a minimum protected by using a strong password. Access to the network should be restricted to authorized users and devices, and default router credentials should always be changed.
2. Keep Network Infrastructure and Devices Up to Date
Cybersecurity vulnerabilities are regularly discovered in networking equipment and connected devices. To reduce the risk of exploitation, routers, access points, firewalls, and other network components should be kept up to date with the latest firmware and security patches.Likewise, inverter software and firmware should be updated regularly to ensure that security enhancements, bug fixes, and reliability improvements are applied in a timely manner.
3. Prefer Wired Network Connections
Whenever practical, Fronius recommends connecting inverters via Ethernet rather than WiFi. Wired connections typically provide greater reliability, lower latency, and reduced susceptibility to wireless attacks such as unauthorized network access, rogue access points, or signal interception.Using wired connectivity can therefore contribute to both improved operational stability and a reduced cybersecurity risk profile.
4. Avoid Direct Internet Exposure
A fundamental cybersecurity principle is to prevent direct exposure of inverters and other system componentes to the public Internet. Inverters should never be made directly accessible from external networks through port forwarding, Port Address Translation (PAT), or similar mechanisms.Instead, remote monitoring and management should be performed using Fronius-approved cloud services, such as Solar.web, or through appropriately secured remote-configuration solutions that implement strong authentication and encryption.
In most residential and commercial environments, inbound network exposure mechanisms such as PAT or port forwarding are disabled by default on Internet routers and must be intentionally enabled through configuration changes. Fronius strongly recommends that these settings remain disabled and that inverter systems are not exposed directly to the public Internet under any circumstances.
Where possible, dedicated firewall devices or advanced router firewall functions should be used to provide an additional layer of protection and to restrict access to authorized systems and services only.
5. Secure the Inverter Access Point
If the inverter is configured to operate as a WiFi access point, administrators should ensure that a strong pre-shared key (PSK) is configured. A password of at least 20 characters containing a combination of uppercase letters, lowercase letters, numbers, and special characters is recommended. Strong authentication credentials significantly reduce the likelihood of unauthorized access through password-guessing or brute-force attacks.
6. Use Secure Communication Protocols
Organizations should carefully evaluate the security characteristics of the communication protocols used within their energy infrastructure. Modbus TCP/IP, while widely adopted for industrial communication, does not provide built-in encryption or authentication and should therefore be considered an unsecured protocol.Where possible, more secure alternatives such as MQTT-based solutions with TLS encryption should be used. Modbus TCP/IP should only be enabled when required for interoperability with existing devices or legacy integrations, and access should be restricted through appropriate network segmentation and firewall controls.
7. Apply Network Segmentation
For commercial and industrial environments, it is recommended to place inverters and other energy-related devices in a dedicated network segment or VLAN. Network segmentation limits the potential impact of a compromised device and helps prevent unauthorized lateral movement within the organization's infrastructure.Access between network segments should be controlled through firewalls and limited to required services and protocols.
8. Enforce Strong Access Control
All administrative accounts should be protected with strong, unique passwords and managed according to the principle of least privilege. Access should be granted only to individuals who require it for operational purposes.Unused accounts, services, and interfaces should be disabled whenever possible to further reduce the system's attack surface.
Conclusion
Fronius inverter platforms incorporate secure-by-design principles and provide robust security mechanisms. However, maintaining a secure deployment requires appropriate network architecture, secure configuration practices, and ongoing maintenance. By implementing these recommendations, customers can significantly reduce cybersecurity risks and help ensure the confidentiality, integrity, and availability of their solar energy systems.