Eco

Please choose your desired product.

Technical Data

Input Data

Number of MPP trackers1
Max. input current (Idc max)
47,7 A
Max. short circuit current, module array*
80 A
DC input voltage range (Udc min - Udc max)
580 - 1000 V
Feed-in start voltage (Udc start)
650 V
Nominal input voltage (Udc,r)
580 V
MPP voltage range (Umpp min - Umpp max)
580 - 850 V
Usable MPP voltage range580 - 850 V
Number of DC connections6
Max. PV generator power (Pdc max
37,8 kWpeak

Output Data

AC nominal output (Pac,r)
27 kW
Max. output power (Pac max)
27 kVA
AC output current (Iac nom)
40,9 / 39,1 A
Grid connection (Uac,r)
3~ NPE 400/230, 3~ NPE 380/220 V
AC voltage range (Umin - Umax)
150 - 275 V
Frequency (fr)
50 / 60 Hz
Frequency range (fmin - fmax)
45 - 65 Hz
Power factor (cos φac,r)
0 - 1 ind./cap.

General Data

Dimension / length227,5 mm
Dimension / width512 mm
Dimension / height751 mm
Dimension / depth227,5 mm
Weight35,5 kg
Weight incl. packaging39,5 kg
Degree of protectionIP 66
Protection class1
Overvoltage category (DC / AC) 1)
2 / 3
Night-time consumption< 1 W
Inverter designTransformerless
CoolingRegulated air cooling
InstallationIndoors and outdoors
Ambient temperature range-25°C - +60°C
Permitted humidity0 - 100 %
Max. altitude 2)
2500 m
DC connection technology6x DC+ and 6x DC- screw terminals 2.5 - 16 mm²
AC connection technology5-pin AC screw terminals 2.5 - 16 mm²
Certificates and compliance with standardsÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727,
AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G99, UNE 206007-1, SI 4777, CEI 0-16, CEI 0-21
Sound emissions60,3 dB(A)
Interference emission classB

Efficiency

Max. efficiency (PV - grid)98,3 %
European efficiency (ηEU)98 %
η at 5% Pac,r 3)
95,9 / 93,1 %
η at 10% Pac,r 3)
96,8 / 95,7 %
η at 20% Pac,r 3)
97,7 / 97,1 %
η at 25% Pac,r 3)
98,1 / 97,3 %
η at 30% Pac,r 3)
98,1 / 97,4 %
η at 50% Pac,r 3)
98,3 / 97,5 %
η at 75% Pac,r 3)
98,2 / 97,6 %
η at 100% Pac,r 3)
98,1 / 97,5 %
MPP adaptation efficiency> 99,9 %

Protection Devices

DC insulation measurementYes
Overload behaviourOperating point shift, power limitation
DC disconnectorYes
Integrated string fuse holderYes
DC Reverse polarity protectionYes

Interfaces

Wi-Fi / Ethernet LANFronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital I/OsInterface to ripple control receiver
USB (type A socket) 4)
Data logging, inverter update via USB flash drive

2 × RS422 (RJ45 socket) 4)

Fronius Solar Net
Signalling output 4)
Energy management (floating relay output)
Datalogger and web serverIntegrated
External input 4)
S0 meter connection / Evaluation of overvoltage protection
RS485Modbus RTU SunSpec or meter connection
Help with installing and using this product.
Smart Grid Ready
1 / 3
Fronius Eco
Smart Grid Ready from Fronius
Fronius SnapINverter with innovative hinged system

Downloads

    Show all downloads for product

    Footnotes for technical data

    1) According to IEC 62109-1. DIN rail for optional type 1 + 2 or type 2 surge protection device available. 

    2) Unrestricted / restricted voltage range. 

    3) And at Umpp min / Udc,r / Umpp max.

    4) Also available in the light version. 

     

    * Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g.: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.