Technical Data

Input Data

Number of MPP trackers1
Recommended PV Power (kWp)12,0 - 19,5 kWp
Max. usable input current50 A
Max. usable input current total (MPPT1 + MPPT2)
50 A
Max. array short circuit current (1.5 * Imax)75 A
Nominal input voltage
325 V
DC input voltage range (Udc min - Udc max)
325 - 1000 V
MPP Voltage Range
325 - 850 V
Max. input voltage (Udc max)
1000 V
Integrated DC string fuse holders6- and 6+

Output Data

Max. output power 480 VNA
Max. output power 240 VNA
Max. output power 208 V15 kVA
Output configuration
3~ NPE 208/220 V
Frequency range45 - 65 Hz
Frequency60 Hz
Power factor range
0 - 1 ind./cap.
Max continuous output current 480 VNA
Max. continuous output current 240 VNA
Max. continuous output current 208 V41,6 A
OCPD/AC breaker size 480 VNA
OCPD/AC breaker size 208 V60 A
Max. efficiency97,3 %
CEC efficiency 480 VNA
CEC efficiency 240 VNA
CEC efficiency 208 V96,5 %

General Data

UL safety standards & network regulationsUL 1741-2015, UL 1998, UL 1699B Issue 2-2013
Dimension / length226 mm
Dimension / width511 mm
Dimension / height724 mm
Dimension / depth226 mm
Weight35,52 kg
Degree of protectionNEMA 4X
Night-time consumption< 1 W
Inverter designTransformerless
CoolingVariable speed fan
Ambient Temperature Range-40°C - +60°C
Maximum Relative Humidity0 - 100 %
Max. altitude2000 m (6560 ft) with a max. input voltage of 1000 V / 3400 m (11160 ft) with a max. input voltage of 850 V
Certificates and compliance with standardsUL 1741-2010, UL1998 (for functions: AFCI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2008, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 ( September 2001), UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013
DC connection technology6x DC+ and 6x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminium (solid / stranded)
AC connection technologyScrew terminals 14-6 AWG
Interference emission classB

Protection Devices

DC reverse polarity protectionYes
Anti islandingInternal in accordance with UL 1741-2005, IEEE 1547-2003 and NEC
Over temperature protectionOutput power derating / Active cooling
AFCIYes
Rapid shutdown compliantYes (according to NEC 2014)
Ground fault protection with isolation monitor interrupterYes
DC disconnectorYes

Interfaces

USB (type A socket)Datalogging and inverter update possible via USB
2x RS422 (RJ45 socket)Fronius Solar Net
Wi-Fi / Ethernet / Serial / Datalogger and webserverWireless standard 802.1 1 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU - Available with the Fronius Datamanager 2.0 Card only
6 inputs and 4 digital I/OsLoad management signaling, multipurpose I/O - Available with the Fronius Datamanager 2.0 Card only