Technical Data
Input Data
| Number of MPP trackers | 2 |
|---|---|
Max. input current (Idc max) | 22 / 12 A |
Max. short circuit current, module array* | 41,25 / 22 A |
DC input voltage range (Udc min - Udc max) | 65 - 600 V |
Feed-in start voltage (Udc start) | 80 V |
Nominal input voltage (Udc,r) | 400 V |
MPP voltage range (Umpp min - Umpp max) | 200 - 530 V |
| Usable MPP voltage range | 65 - 530 V |
| Number of DC connections | 2+2 |
| Min. MPP voltage (Umpp min) | 200 V |
| Max. MPP voltage (Umpp max) | 530 V |
Max. PV generator power (Pdc max) | 5,52 kWpeak |
Output Data
AC nominal output (Pac,r) | 3680 W |
|---|---|
Max. output power (Pac max) | 3680 VA |
| Max. grid power demand | 3680 VA |
| Max. AC output current | 23,7 A |
Grid connection (Uac,r) | 1~ NPE 220/230 V |
AC voltage range (Umin - Umax) | 155 - 270 V |
Frequency (fr) | 50 / 60 Hz |
Frequency range (fmin - fmax) | 45 - 65 Hz |
Power factor (cos φac,r) | 0,8 - 1 ind./cap. |
| Back-up power | 1~NPE 220 V / 230 V |
| Nom. output current (220VAC) | 16.7 A |
| Nom. output current (230VAC) | 16 A |
Output Data PV Point
| Max continuous output power | 3000 VA |
|---|---|
Nom. output current (Iac max) | 13 A |
| Grid connection | 1~NPE 220 V / 230 V |
| Frequency | 50 Hz / 60 Hz |
| Max. switchover time PV-Point | 15 s |
| Frequency in backup power mode | 53 Hz |
General Data
| Dimension / length | 165 mm |
|---|---|
| Dimension / width | 474 mm |
| Dimension / height | 530 mm |
| Dimension / depth | 165 mm |
| Weight | 15,38 kg |
| Weight incl. packaging | 19 kg |
| Degree of protection | IP66 |
| Protection class | 1 |
Overvoltage category (DC / AC) 1) | 2 / 3 |
| Night-time consumption | < 10 W |
| Inverter design | Trafolos |
| Cooling | Active cooling |
| Installation | Indoor and outdoor installation |
| Ambient temperature range | -40°C - +60°C |
| Permitted humidity | 0 - 100 % |
Max. altitude 2) | 4000 m |
| DC PV connection technology | 4x DC+ and 4x DC- push-in spring-loaded terminals 2.5 - 10 mm² |
| AC connection technology | 3-pole AC push-in spring-loaded terminals 2.5 - 10 mm² 3-pole backup power push-in spring-loaded terminals 1.5 mm² - 10 mm² 2x PE screw terminals 2.5 - 16 mm² and 3x 2.5 - 10 mm² |
| Certificates and compliance with standards | IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 and 16150, IEC 62116, IEC 61727,G98/G994) |
| Back-up power functions | PV Point |
| Sound emissions | 42 dB(A) |
| Interference emission class | B |
Efficiency
| Max. efficiency (PV - grid) | 97,6 % |
|---|---|
| European efficiency (ηEU) | 95.6 / 97.0 / 96.3 (200Vdc / 400Vdc / 530Vdc) |
η at 5% Pac,r 3) | 85.3 / 90.2 / 87.9 (200Vdc / 400Vdc / 530Vdc) |
η at 10% Pac,r 3) | 89.5 / 93.2 / 91.5 (200Vdc / 400Vdc / 530Vdc) |
η at 20% Pac,r 3) | 94.0 / 96.1 / 95.3 (200Vdc / 400Vdc / 530Vdc) |
η at 25% Pac,r 3) | 94.8 / 96.6 / 96.0 (200Vdc / 400Vdc / 530Vdc) |
η at 30% Pac,r 3) | 95.4 / 96.9 / 96.3 (200Vdc / 400Vdc / 530Vdc) |
η at 50% Pac,r 3) | 96.3 / 97.4 / 97.0 (200Vdc / 400Vdc / 530Vdc) |
η at 75% Pac,r 3) | 96.6 / 97.5 / 97.3 (200Vdc / 400Vdc / 530Vdc) |
η at 100% Pac,r 3) | 96.7 / 97.5 / 97.3 (200Vdc / 400Vdc / 530Vdc) |
| MPP adaptation efficiency | 99.9 |
Protection Devices
| DC insulation measurement | Yes |
|---|---|
| Overload behaviour | Operating point shift, power limitation |
| DC disconnector | Yes |
| DC Reverse polarity protection | Yes |
Interfaces
| WLAN / 2x Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
|---|---|
| 6x digital in/out + 6x digital in | Connection to ripple control receivers, energy management |
| Emergency stop (WSD) | Yes |
| Datalogger and web server | Integrated |
| 2x RS485 | Modbus RTU SunSpec (third-party provider) / Fronius Smart Meter, battery, Fronius Ohmpilot |
Overview of advantages, features, and possible applications.
Help with installing and using this product.
Frequently searched downloads
Downloads
Show all downloads for product
Footnotes for technical data
1) According to IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK
2) Unrestricted voltage range.
3) At Umpp min. / Udc,r / Umpp max.
4) You can find the current certificates under www.fronius.com/primo-gen24-plus-cert
* Isc pv = Isc max ≥ Isc (STC) x 1,25 according to e.g.: IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.